Original: $375.99
-70%$375.99
$112.80The Story
The Thermal Infusion Set (TIS, NAR item 35-0004) is the QUANTUM Blood & Fluid Warming System's specialized IV administration tubing for crystalloid and IV fluid applications. Weighing 2.3 oz, it integrates heating elements and thermistors directly into the tubing wall, enabling the QUANTUM Controller to warm IV fluids from 68°F to 100.4°F (38°C ± 2°C) in 24 seconds at flow rates up to 200 mL/min — with 80 in of total tubing length and a priming volume of approximately 16 mL.
Key Specifications
| Specification | Detail |
|---|---|
| Manufacturer | North American Rescue (NAR) |
| SKU / Item # | 35-0004 |
| Weight | 2.3 oz |
| Tubing Length | 80 in |
| Priming Volume | Approximately 16 mL |
| Compatible Fluids | IV solutions only (crystalloids, colloids) — NOT for blood or blood products |
| Max Flow Rate | Up to 200 mL/min |
| Input Temp (Rated) | 68°F (20°C) |
| Output Temperature | 100.4°F (38°C ± 2°C) |
| Warming Capacity per Charge | Approximately 1,700 mL |
| Warmup Time | 24 seconds |
| Drip Rate | 20 drops/mL |
Product Overview
The Thermal Infusion Set is the IV-fluids-only thermal tubing set for the QUANTUM Blood & Fluid Warming System. It is distinct from the Thermal Transfusion Set–Blood (TTS-B, 35-0005), which is cleared for blood, blood products, and IV fluids. The TIS is the appropriate set when the QUANTUM is being used solely for warming crystalloid or colloid IV solutions — not blood — allowing organizations to use a lower-cost consumable for non-blood warming applications and reserve the TTS-B for blood transfusion events.
Like the TTS-B, the TIS incorporates a conductive heating element between the inner and outer tubing walls (outside the fluid path) and thermistors that continuously report temperature data to the QUANTUM Controller. The controller uses this feedback to dynamically modulate heating, maintaining a consistent output temperature of 100.4°F (38°C ± 2°C) regardless of flow rate variation. Setup is identical to a standard IV set with the addition of the controller cable connection.
The TIS is available in packs of 2 (item 35-0004 as packaged). For organizations using the QUANTUM primarily for IV fluid warming rather than blood transfusion, stocking TIS sets alongside a smaller supply of TTS-B sets for blood events is a logical approach to consumable management.
See also: IV/IO & Blood Transfusion Supplies | Massive Hemorrhage Control
All products sourced from the actual brand manufacturer or authorized master distributors. CoTCCC recommendation status verified where applicable. Ships from MED-TAC International, Pembroke Pines, FL — clinician-founded, veteran-led, SDVOSB-certified.

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.
Description
The Thermal Infusion Set (TIS, NAR item 35-0004) is the QUANTUM Blood & Fluid Warming System's specialized IV administration tubing for crystalloid and IV fluid applications. Weighing 2.3 oz, it integrates heating elements and thermistors directly into the tubing wall, enabling the QUANTUM Controller to warm IV fluids from 68°F to 100.4°F (38°C ± 2°C) in 24 seconds at flow rates up to 200 mL/min — with 80 in of total tubing length and a priming volume of approximately 16 mL.
Key Specifications
| Specification | Detail |
|---|---|
| Manufacturer | North American Rescue (NAR) |
| SKU / Item # | 35-0004 |
| Weight | 2.3 oz |
| Tubing Length | 80 in |
| Priming Volume | Approximately 16 mL |
| Compatible Fluids | IV solutions only (crystalloids, colloids) — NOT for blood or blood products |
| Max Flow Rate | Up to 200 mL/min |
| Input Temp (Rated) | 68°F (20°C) |
| Output Temperature | 100.4°F (38°C ± 2°C) |
| Warming Capacity per Charge | Approximately 1,700 mL |
| Warmup Time | 24 seconds |
| Drip Rate | 20 drops/mL |
Product Overview
The Thermal Infusion Set is the IV-fluids-only thermal tubing set for the QUANTUM Blood & Fluid Warming System. It is distinct from the Thermal Transfusion Set–Blood (TTS-B, 35-0005), which is cleared for blood, blood products, and IV fluids. The TIS is the appropriate set when the QUANTUM is being used solely for warming crystalloid or colloid IV solutions — not blood — allowing organizations to use a lower-cost consumable for non-blood warming applications and reserve the TTS-B for blood transfusion events.
Like the TTS-B, the TIS incorporates a conductive heating element between the inner and outer tubing walls (outside the fluid path) and thermistors that continuously report temperature data to the QUANTUM Controller. The controller uses this feedback to dynamically modulate heating, maintaining a consistent output temperature of 100.4°F (38°C ± 2°C) regardless of flow rate variation. Setup is identical to a standard IV set with the addition of the controller cable connection.
The TIS is available in packs of 2 (item 35-0004 as packaged). For organizations using the QUANTUM primarily for IV fluid warming rather than blood transfusion, stocking TIS sets alongside a smaller supply of TTS-B sets for blood events is a logical approach to consumable management.