🚚 Free Worldwide Shipping on All Orders!Shop Now
Thermal Infusion Set
HomeStore

Thermal Infusion Set

Thermal Infusion Set

$112.80

Original: $375.99

-70%
Thermal Infusion Set—

$375.99

$112.80

The Story

The Thermal Infusion Set (TIS, NAR item 35-0004) is the QUANTUM Blood & Fluid Warming System's specialized IV administration tubing for crystalloid and IV fluid applications. Weighing 2.3 oz, it integrates heating elements and thermistors directly into the tubing wall, enabling the QUANTUM Controller to warm IV fluids from 68°F to 100.4°F (38°C ± 2°C) in 24 seconds at flow rates up to 200 mL/min — with 80 in of total tubing length and a priming volume of approximately 16 mL.

Key Specifications

Specification Detail
Manufacturer North American Rescue (NAR)
SKU / Item # 35-0004
Weight 2.3 oz
Tubing Length 80 in
Priming Volume Approximately 16 mL
Compatible Fluids IV solutions only (crystalloids, colloids) — NOT for blood or blood products
Max Flow Rate Up to 200 mL/min
Input Temp (Rated) 68°F (20°C)
Output Temperature 100.4°F (38°C ± 2°C)
Warming Capacity per Charge Approximately 1,700 mL
Warmup Time 24 seconds
Drip Rate 20 drops/mL

Product Overview

The Thermal Infusion Set is the IV-fluids-only thermal tubing set for the QUANTUM Blood & Fluid Warming System. It is distinct from the Thermal Transfusion Set–Blood (TTS-B, 35-0005), which is cleared for blood, blood products, and IV fluids. The TIS is the appropriate set when the QUANTUM is being used solely for warming crystalloid or colloid IV solutions — not blood — allowing organizations to use a lower-cost consumable for non-blood warming applications and reserve the TTS-B for blood transfusion events.

Like the TTS-B, the TIS incorporates a conductive heating element between the inner and outer tubing walls (outside the fluid path) and thermistors that continuously report temperature data to the QUANTUM Controller. The controller uses this feedback to dynamically modulate heating, maintaining a consistent output temperature of 100.4°F (38°C ± 2°C) regardless of flow rate variation. Setup is identical to a standard IV set with the addition of the controller cable connection.

The TIS is available in packs of 2 (item 35-0004 as packaged). For organizations using the QUANTUM primarily for IV fluid warming rather than blood transfusion, stocking TIS sets alongside a smaller supply of TTS-B sets for blood events is a logical approach to consumable management.

See also: IV/IO & Blood Transfusion Supplies | Massive Hemorrhage Control

All products sourced from the actual brand manufacturer or authorized master distributors. CoTCCC recommendation status verified where applicable. Ships from MED-TAC International, Pembroke Pines, FL — clinician-founded, veteran-led, SDVOSB-certified.

Thermal Infusion Set - Image 2

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Thermal Infusion Set - Image 3

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Thermal Infusion Set - Image 4

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Thermal Infusion Set - Image 5

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Description

The Thermal Infusion Set (TIS, NAR item 35-0004) is the QUANTUM Blood & Fluid Warming System's specialized IV administration tubing for crystalloid and IV fluid applications. Weighing 2.3 oz, it integrates heating elements and thermistors directly into the tubing wall, enabling the QUANTUM Controller to warm IV fluids from 68°F to 100.4°F (38°C ± 2°C) in 24 seconds at flow rates up to 200 mL/min — with 80 in of total tubing length and a priming volume of approximately 16 mL.

Key Specifications

Specification Detail
Manufacturer North American Rescue (NAR)
SKU / Item # 35-0004
Weight 2.3 oz
Tubing Length 80 in
Priming Volume Approximately 16 mL
Compatible Fluids IV solutions only (crystalloids, colloids) — NOT for blood or blood products
Max Flow Rate Up to 200 mL/min
Input Temp (Rated) 68°F (20°C)
Output Temperature 100.4°F (38°C ± 2°C)
Warming Capacity per Charge Approximately 1,700 mL
Warmup Time 24 seconds
Drip Rate 20 drops/mL

Product Overview

The Thermal Infusion Set is the IV-fluids-only thermal tubing set for the QUANTUM Blood & Fluid Warming System. It is distinct from the Thermal Transfusion Set–Blood (TTS-B, 35-0005), which is cleared for blood, blood products, and IV fluids. The TIS is the appropriate set when the QUANTUM is being used solely for warming crystalloid or colloid IV solutions — not blood — allowing organizations to use a lower-cost consumable for non-blood warming applications and reserve the TTS-B for blood transfusion events.

Like the TTS-B, the TIS incorporates a conductive heating element between the inner and outer tubing walls (outside the fluid path) and thermistors that continuously report temperature data to the QUANTUM Controller. The controller uses this feedback to dynamically modulate heating, maintaining a consistent output temperature of 100.4°F (38°C ± 2°C) regardless of flow rate variation. Setup is identical to a standard IV set with the addition of the controller cable connection.

The TIS is available in packs of 2 (item 35-0004 as packaged). For organizations using the QUANTUM primarily for IV fluid warming rather than blood transfusion, stocking TIS sets alongside a smaller supply of TTS-B sets for blood events is a logical approach to consumable management.

See also: IV/IO & Blood Transfusion Supplies | Massive Hemorrhage Control

All products sourced from the actual brand manufacturer or authorized master distributors. CoTCCC recommendation status verified where applicable. Ships from MED-TAC International, Pembroke Pines, FL — clinician-founded, veteran-led, SDVOSB-certified.